Envision Medica
Envision Medica
New Delhi, Delhi
Send SMS
Send E-mail

MEDA, China

Including ophthalmology A / B ultrasonic diagnostic apparatus, ophthalmic ultrasonic measuring instrument, ophthalmic ultrasound biomicroscope, ophthalmology, including ophthalmic ultrasound diagnosis equipment.
Get CALLBACK

AB Scan for Ophthalmology

AB Scan for Ophthalmology
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ApplicationHospital, Clinical
ModelModel AB Scan 2300S
BrandMeda
Dynamic Replay10 sec
A Probe with10MHz
Accuracy+- 0.05mm
Measuring Range15 ~ 40mm

TGC: 
  • TGC (Time Gain Control) enhances segmental imaging gain. 5 segment TGC adjustable within range - 30dB to 0dB. Applicable default and customized settings.
 B+B:
  • Dual B mode enables image video review and comparison. Dedicated for Omni-dimension ocular disease observation.
 Zoom and Delay:
  •  Enlarge the diagnostic image by different zooming level. 6 zooming rate adjustable. Diagnostic image shifting from posterior segment to anterior segment.
 Powerful Post Processing: 
  • Distance and Area measurement. Simultaneous display of multiple groups of distance and area reading. Freezing diagnostic images storage dynamic cine review.
 Five-Point Measurement:
  • Innovative AL measurement method under A+B mode. Combine biometric measurement with ocular image display.
 A-SCAN:
  • Integration of AL measurement and IOL calculation.
  • The diagnostic solution for cataract surgery.
  • Reading average and standard deviation improves reading accuracy and liability.
  • Contact Immersion measuring method.
  • 4 automatic mode: Normal, Cataract, Aphakic and Special.
  • Manual measuring available.
 Iol Calculation: 
  • 6 Popular Iol Formulae: Srk-T, Srk-Ii, Binkhost-Ii, Holladay, Hoffer-Q, Haigis
  • Dual Formulae Display for Result Comparison
 The PC Connection: 
  • Patient management system enables massive patient case study storage and assists to generate customizes clinical report and printing.
 Clinical Gallery:
  • VItreous Haematocele
  • Retina Detachment
  • Vitreous Organization
 Accessories:
  • 10MHz A-Probe
  • 10MHz B-Probe
  • Foot Switch
 Options:
  • Eye Cup
  • Video Thermal Printer
  • Workstation PC Suite
Yes! I am Interested
Get CALLBACK

A Scan Biometer

A Scan Biometer
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ApplicationHospital, Clinical
ModelMD-1000A
BrandMedica International
Probe10MHz with Fixation Red Light
Total Gain100dB with an adjustable range of 0-50dB
Biometry Accuracy+- 0.05mm
Resolution0.01mm
Measuring Range15 - 40 mm
Measuring ModeContact to Immersion
Measuring ParametersAnterior Chamber Depth, Lens Thickness, Vitreous Length
Measuring ModesAutomatic (Normal, Cataract, Aphakic and Special) and Manual

Due to our proficiency of this field, we are engaged in presenting A Scan Biometer. We are presenting these products to customers within given time-frame. A-Biometry:
  • Precise Accurate: A-Scan precision and accuracy, under both cataract and immersion mode, are ensured by MEDA's mature technology and professional expertise in the ophthalmic field.
  • Reliable: Up to 8 groups of readings automatically measured per each group, with averaging and standard deviation for a higher level of reliability.
  • Comprehensive: Automatic measurements for 4 different eye types: normal, cataract, Aphakic and special, Manual measurement also available.
  • Convenient: Touch screen and foot switch equipped to enable smooth operations.
  • IOL Formulae: 6 Popular formulae for IOL calculation; 5 major formulae for post-refractive IOL calculation.
  • Intuitive Interface: Instant switch among different formulae; Dual-formula display for direct result comparison.
  • Simple Operations: Higher accessibility of database; Single click for instant printout.
  • Tight Integration: Easy access between A-Scan and IOL; Axial length automatically imported from A-Scan measurement.
  • Accurate Results: Automatic reading at single or multiple points for corneal thickness; Multiple measurements at a single point for higher reliability; Higher accuracy enabled by averaging readings.
  • IOP Adjustment: Intraocular pressure for adjustment provides a reference for tonometer measurement; Parameter adjustability based on user's experience.
 Management:
  • Patient Management: Built-in data archiving capability for storage of up to 180 patient records.
  • PC Connectivity: Uploading application software developed to allow for communications with PC and unlimited storage capability.
  • Instant Printout: Single click print-out enabled by the in-built thermal printer; User-defined print-out options.
  • User-defined Preference: Users are free to define acoustic velocities, IOP parameters and printing options.
 Features:
  • Accurate measurements under both Contact and Immersion modes
  • Extreme ease of use touch screen
  • Automatic / Manual modes
  • Auto gain control
  • Built-in thermal printer
  • Portable ergonomic design

Price Range:
  • Rs. 150000 to Rs.175000
Yes! I am Interested
View PDF
Get CALLBACK

Ultrasonic A B Scan Ophthalmology

Ultrasonic A B Scan Ophthalmology
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ApplicationHospital
BrandMEDA.,CO.LTD.
Voltage100 - 240 V AC
Frequency50 - 60 Hz
Weight10 Kg
Dimension360 x 300 x 260 mm
ModelODM-2100

We are one of the foremost firms of Ultrasonic A B Scan Ophthalmology. Besides, we present this product at nominal rates to our customers. Price Range:
  • Rs. 550000 to Rs. 650000
Yes! I am Interested
View PDF
Explore More Products
Get Best Quote
Get Best Quote
Get Best Quote
Get Best Quote
Get Best Quote
Get Best Quote
X
Looking for “MEDA, China”?
Find Us Pankaj Sain (President) 112, Ansal Majestic Tower Vikaspuri, New Delhi - 110018, Delhi, India
SEND SMS
SEND E-MAIL
Share Us: